We found your home
WILLOTT COTTAGE, WILMSLOW ROAD
Estimated boiler replacement
£1,900–£3,200
For a detached like yours · estimated installed cost
Your options for this home
Boiler replacement
Estimated installed cost · 20–26.5 kW
- Fuel confirmed on survey
- Suitable for your home size
- Combi or system options
See details →
- • Preliminary heat requirement 20.0–26.5 kW from 249.0 m² and construction era 1950s.
- • Heating system type to be confirmed on survey.
New central heating
Complete system estimate · 20–26.5 kW
- Boiler / heat source
- Radiators (~23)
- Pipework & controls
See details →
- • A complete new system priced on ~23 radiators, pipework and a boiler.
- • Radiator count is indicative from floor area and confirmed on survey.
Home air conditioning
Multi-split system estimate · 4–6 kW · ~3 units
- Approx. 3 indoor units
- Heating & cooling
- Professional installation
See details →
- • Total floor area is not the same as conditioned area; this reflects the selected room scenario.
Heating & cooling profile
Using the recorded floor area and EPC characteristics, this 249m² 1950s detached home has a current EPC rating of D55 and its recorded heating. HotAndCold estimates a space-heating requirement of approximately 20.0–26.5kW. The recorded EPC score places this home in the middle of the efficiency range. Its modelled space-heating intensity per square metre is moderate.
Hot&Cold snapshot
What stands out about this home
Why this estimate?
We calculate estimates using your property's size, type, age, heating fuel and EPC rating, along with typical installation costs, not a professional heat-loss survey.
How we calculated this
What we found about your home
- Property type
- Detached
- Floor area
- 249 m²
- Energy rating
- EPC D55
- Main heating fuel
- Oil
- Approx. age
- 1950s
- Location
- NEWTON, Cheshire East
We use publicly available data and industry models to generate this estimate. A final survey by an installer may vary.
How this home compares locally
Based on 7 EPC-recorded properties nearby.
Building
- Built form
- Detached
- Internal area (EPC)
- 249 m²
- Building footprint
- ~123 m²
- Approx. dimensions
- ~17.8 × 9.8 m
- Main building axis
- N–S
- Nearest building
- 15.2 m
Footprint & dimensions derived from Overture Maps building data (ODbL). Approximate, not survey-grade.
How this home is constructed & heated
Recorded on its Energy Performance Certificate.
- Walls
- Cavity wall, filled cavity
- Roof
- Pitched, insulated at rafters
- Windows
- Fully double glazed
- Main heating
- Boiler and radiators, LPG, Boiler and underfloor heating, LPG
- Heating controls
- Time and temperature zone control
- Hot water
- From main system
- Floor
- Solid, insulated
Energy improvement potential
Recommended improvements for this property
Measures from this home’s official Energy Performance Certificate assessment that could raise its rating and cut running costs, specific to WILLOTT COTTAGE, WILMSLOW ROAD, NEWTON, MACCLESFIELD, SK10 4LG.
- 1Solar photovoltaic panels, 2.5 kWpIndicative cost: £3,500 - £5,500
A solar PV system is one which converts light directly into electricity via panels placed on the roof with no waste and no emissions. This electricity is used throughout the home in the same way as the electricity purchased from an energy supplier. The British Photovoltaic Association has up-to-date information on local installers who are qualified electricians. It is best to obtain advice from a qualified electrician. Ask the electrician to explain the options.
- 2Solar water heatingIndicative cost: £4,000 - £6,000
A solar water heating panel, usually fixed to the roof, uses the sun to pre-heat the hot water supply. This will significantly reduce the demand on the heating system to provide hot water and hence save fuel and money. The Solar Trade Association has up-to-date information on local installers.
- 3Wind turbineIndicative cost: £15,000 - £25,000
A wind turbine provides electricity from wind energy. This electricity is used throughout the home in the same way as the electricity purchased from an energy supplier. The British Wind Energy Association has up-to-date information on suppliers of small-scale wind systems. Wind turbines are not suitable for all properties. The system’s effectiveness depends on local wind speeds and the presence of nearby obstructions, and a site survey should be undertaken by an accredited installer.
Source: the property’s domestic EPC recommendations (open data). Indicative only, get a professional survey before committing to any measure.
Energy rating history
Recorded change: -2 EPC points across 2 certificates.
- 2015D57
- 2025D55
Common questions
How much does a replacement boiler cost for a property like this?+
For this property we estimate an installed cost of £1,900–£3,200. This is indicative and based on the property's size, type and energy characteristics, your final price depends on equipment choice and an installer survey.
What size boiler might this property need?+
Our preliminary model estimates a heat requirement of around 20–26.5 kW. An installer confirms exact sizing on a heat-loss assessment.
How much would air conditioning cost here?+
A multi-split installation is estimated at £3,800–£5,700, depending on how many rooms you want to cool (around 3 indoor units in a typical layout).
Are these guaranteed prices?+
No, they are indicative estimates to help you understand likely costs before speaking to an installer. Your final price depends on equipment choice, installation complexity and a survey.
Other homes nearby
Ready to get exact prices?
Compare no-obligation quotes from vetted local installers for your property.