Hot&Cold.energy

We found your home

13 HURLEY DRIVE, CHEADLE HULME

End-terrace83 m²EPC C72Electric1950s

Estimated boiler replacement

£1,900–£3,200

For a end-terrace like yours · estimated installed cost

FreeNo obligationLocal installers

Your options for this home

Boiler replacement

£1,900–£3,200

Estimated installed cost · 5.5–7 kW

  • Fuel confirmed on survey
  • Suitable for your home size
  • Combi or system options
See details
  • Preliminary heat requirement 5.5–7.0 kW from 83.0 m² and construction era 1950s.
  • Heating system type to be confirmed on survey.

New central heating

£3,940–£6,360

Complete system estimate · 6–7.5 kW

  • Boiler / heat source
  • Radiators (~8)
  • Pipework & controls
See details
  • A complete new system priced on ~8 radiators, pipework and a boiler.
  • Radiator count is indicative from floor area and confirmed on survey.

Home air conditioning

£3,800–£5,700

Multi-split system estimate · 4–6 kW · ~3 units

  • Approx. 3 indoor units
  • Heating & cooling
  • Professional installation
See details
  • Total floor area is not the same as conditioned area; this reflects the selected room scenario.

Heating & cooling profile

HotAndCold's model combines the recorded floor area, property type and EPC data, so this 83m² 1950s end-terrace home has a current EPC rating of C72 and its recorded heating. HotAndCold estimates a space-heating requirement of approximately 5.5–7.0kW. This property has relatively strong recorded energy efficiency. Its modelled space-heating intensity per square metre is moderate.

Estimated space-heating intensity
6684 W/m²
moderateProperty data confidence: Good

Hot&Cold snapshot

Property size
Typical
Energy efficiency
Higher
Heating intensity
Moderate
Improvement potential
Moderate
Main heating fuel
Non-gas
Cooling requirement
Medium

What stands out about this home

Unusual heating fuel for this street

Why this estimate?

We calculate estimates using your property's size, type, age, heating fuel and EPC rating, along with typical installation costs, not a professional heat-loss survey.

How we calculated this

83 m²
Floor area
+
end terrace
Property type
+
EPC C72
Energy rating
Hot&Cold property model
5.5–7 kW
Estimated heating requirement for this property

What we found about your home

Property type
End-terrace
Floor area
83 m²
Energy rating
EPC C72
Main heating fuel
Electric
Approx. age
1950s
Location
CHEADLE, Stockport

We use publicly available data and industry models to generate this estimate. A final survey by an installer may vary.

How this home compares locally

Based on 16 EPC-recorded properties nearby.

Floor area
-7%
7% smaller than the local median
EPC rating
+3
3 EPC points above the local median
Mains gas
94%
94% of nearby EPC-recorded homes use mains gas
Property type
25%
this property type is 25% of nearby recorded homes

Sale history

Recorded sales for 13 HURLEY DRIVE from HM Land Registry Price Paid data.

  1. £159,000
    Dec 2015 · Terraced

Contains HM Land Registry data © Crown copyright and database right. Sale prices are historic and not a current valuation.

Building

Built form
End-terrace
Internal area (EPC)
83 m²
Building footprint
~446 m²
Approx. dimensions
~47.4 × 13.7 m
Main building axis
E–W
Estimated floors
1
Nearest building
6.9 m

Footprint & dimensions derived from Overture Maps building data (ODbL). Approximate, not survey-grade.

How this home is constructed & heated

Recorded on its Energy Performance Certificate.

Walls
Cavity wall, filled cavity
Roof
Pitched, 200 mm loft insulation
Windows
Fully double glazed
Main heating
Electric storage heaters
Heating controls
Manual charge control
Hot water
Electric immersion, off-peak
Floor
Solid, no insulation (assumed)

Energy improvement potential

Current
C72
Potential
B83
+11
Moderate improvement potential

Recommended improvements for this property

Measures from this home’s official Energy Performance Certificate assessment that could raise its rating and cut running costs, specific to 13 HURLEY DRIVE, CHEADLE HULME, CHEADLE, SK8 6DH.

  1. 1
    Fan-assisted storage heatersIndicative cost: £1500 - £2000

    Modern storage heaters are smaller and easier to control than the older type in the property. Ask for a quotation for new, fan-assisted heaters with automatic charge control. As installations should be in accordance with the current regulations covering electrical wiring, only a qualified electrician should carry out the installation. It is best to obtain advice from a qualified heating engineer. Ask the engineer to explain the options which might also include switching to other forms of electric heating.

  2. 2
    Low energy lighting for all fixed outletsIndicative cost: £40

    Replacement of traditional light bulbs with energy saving recommended ones will reduce lighting costs over the lifetime of the bulb, and they last up to 12 times longer than ordinary light bulbs. Also consider selecting low energy light fittings when redecorating; contact the Lighting Association for your nearest stockist of Domestic Energy Efficient Lighting Scheme fittings.

  3. 3
    Solar water heatingIndicative cost: £4,000 - £6,000

    A solar water heating panel, usually fixed to the roof, uses the sun to pre-heat the hot water supply. This will significantly reduce the demand on the heating system to provide hot water and hence save fuel and money. The Solar Trade Association has up-to-date information on local installers.

  4. 4
    Floor insulationIndicative cost: £800 - £1,200

    Insulation of a floor will significantly reduce heat loss; this will improve levels of comfort, reduce energy use and lower fuel bills. Suspended floors can sometimes be insulated from below which means that the floor does not need to be lifted to install the insulation. Further information about floor insulation and details of local contractors can be obtained from the National Insulation Association (www.nationalinsulationassociation.org.uk).

  5. 5
    Increase hot water cylinder insulationIndicative cost: £15 - £30

    Increasing the thickness of existing insulation around the hot water cylinder will help to maintain the water at the required temperature; this will reduce the amount of energy used and lower fuel bills. An additional cylinder jacket or other suitable insulation layer can be used. The insulation should be fitted over any thermostat clamped to the cylinder. Hot water pipes from the hot water cylinder should also be insulated, using pre-formed pipe insulation of up to 50 mm thickness (or to suit the space available) for as far as they can be accessed to reduce losses in summer. All these materials can be purchased from DIY stores and installed by a competent DIY enthusiast.

Source: the property’s domestic EPC recommendations (open data). Indicative only, get a professional survey before committing to any measure.

A
B
C
D
E
F
G
Current: C72Potential: B83

Common questions

How much does a replacement boiler cost for a property like this?+

For this property we estimate an installed cost of £1,900–£3,200. This is indicative and based on the property's size, type and energy characteristics, your final price depends on equipment choice and an installer survey.

What size boiler might this property need?+

Our preliminary model estimates a heat requirement of around 5.5–7 kW. An installer confirms exact sizing on a heat-loss assessment.

How much would air conditioning cost here?+

A multi-split installation is estimated at £3,800–£5,700, depending on how many rooms you want to cool (around 3 indoor units in a typical layout).

Are these guaranteed prices?+

No, they are indicative estimates to help you understand likely costs before speaking to an installer. Your final price depends on equipment choice, installation complexity and a survey.

Other homes nearby

Ready to get exact prices?

Compare no-obligation quotes from vetted local installers for your property.