Hot&Cold.energy

Commercial heating & cooling profile

Factory And Premises

RANGEMASTER, CLARENCE STREET, LEAMINGTON SPA, WARWICKSHIRE

Major commercial installation, indicative project

£134,600–£233,600

24754.9 m²
Total measured area
3767.5 m²
Likely conditioned
4
Floors
94
Cooling zones (est.)

Measured floor / use breakdown

FloorDescriptionUseArea m²Conditioned?
GroundProduction Areaancillary1253.2No
GroundInternal Storagestorage71.1No
GroundInternal Storagestorage36.2No
GroundInternal Storagestorage453.6No
GroundProduction Areaancillary125.9No
GroundInternal Storagestorage37.9No
GroundProduction Areaancillary210.7No
FirstInternal Storagestorage210.7No
GroundProduction Areaancillary140.5No
GroundProduction Areaancillary1723.6No
GroundInternal Storagestorage51.3No
MezzanineInternal Storagestorage47.4No
FirstOfficeoffice785.0Yes
FirstOfficeoffice297.1Yes
SecondOfficeoffice359.6Yes
SecondOfficeoffice396.1Yes
SecondOfficeoffice14.3Yes
SecondOfficeoffice297.1Yes
GroundOfficeoffice329.5Yes
GroundProduction Areaancillary17.7No
GroundProduction Areaancillary534.6No
FirstProduction Areaancillary530.1No
GroundOfficeoffice72.4Yes
FirstProduction Areaancillary245.3No
FirstProduction Areaancillary961.6No
FirstOfficeoffice13.4Yes
SecondOfficeoffice58.6Yes
SecondBoard Roomancillary69.5No
SecondCanteenancillary197.2No
SecondKitchenkitchen98.8Yes
SecondCanteenancillary254.7No
SecondOfficeoffice62.6Yes
SecondUnclassified Areaancillary9.5No
SecondComputer Roomancillary401.0No
SecondOfficeoffice320.8Yes
FirstProduction Areaancillary1755.0No
FirstProduction Areaancillary78.0No
GroundOfficeoffice17.3Yes
GroundProduction Areaancillary1810.0No
GroundPlant Roomplant18.4No
FirstOfficeoffice22.3Yes
GroundProduction Areaancillary230.6No
GroundProduction Areaancillary312.2No
MezzanineProduction Areaancillary230.6No
GroundOfficeoffice41.5Yes
GroundOfficeoffice129.2Yes
FirstOfficeoffice42.2Yes
GroundProduction Areaancillary70.5No
GroundLaboratoryancillary16.6No
GroundPlant Roomplant389.4No
GroundProduction Areaancillary381.6No
GroundProduction Areaancillary94.8No
GroundOfficeoffice34.4Yes
GroundProduction Areaancillary147.4No
GroundPlant Roomplant64.0No
GroundProduction Areaancillary2253.2No
GroundProduction Areaancillary329.7No
GroundStorestorage100.4No
GroundStorestorage308.3No
GroundStorestorage124.3No
GroundInternal Storagestorage104.1No
GroundOfficeoffice102.7Yes
GroundProduction Areaancillary648.5No
GroundOfficeoffice15.7Yes
GroundInternal Storagestorage45.8No
GroundMess/Staff Roomancillary14.1No
FirstProduction Areaancillary626.6No
FirstOfficeoffice4.6Yes
FirstStorestorage442.8No
GroundWarehousewarehouse1912.0No
GroundStorestorage167.0No
GroundOfficeoffice51.4Yes
GroundStorestorage238.0No
GroundOfficeoffice80.2Yes
GroundKitchenkitchen5.5Yes
GroundPlant Roomplant28.2No
FirstWorks Officeoffice115.2Yes
MezzanineMess/Staff Roomancillary34.0No
SecondProduction Areaancillary396.7No
SecondInternal Storagestorage31.3No

VOA rateable value is not market value or an annual rates bill. These figures are preliminary and based on public VOA measurements, not an engineering design. A commercial specialist confirms the cooling design on survey.

Other commercial premises nearby in CV31