Commercial heating & cooling profile
Factory And Premises
GEC AVERY LTD, FOUNDRY LANE, SMETHWICK, WEST MIDLANDS
Major commercial installation, indicative project
£820,600–£1,409,600
31074.2 m²
Total measured area
23377.4 m²
Likely conditioned
4
Floors
584
Cooling zones (est.)
Measured floor / use breakdown
| Floor | Description | Use | Area m² | Conditioned? |
|---|---|---|---|---|
| Ground | Production Area | ancillary | 1740.0 | No |
| Ground | Production Area | ancillary | 413.9 | No |
| First | Office | office | 413.9 | Yes |
| Basement | Warehouse | warehouse | 619.6 | No |
| Ground | Workshop | retail | 731.0 | Yes |
| Basement | Internal Storage | storage | 664.7 | No |
| Ground | Workshop | retail | 871.9 | Yes |
| Ground | Laboratory | ancillary | 1341.5 | No |
| Ground | Warehouse | warehouse | 1839.6 | No |
| Ground | Plant Room | plant | 11.8 | No |
| Ground | Workshop | retail | 2147.1 | Yes |
| Basement | Workshop | retail | 1342.0 | Yes |
| Ground | Workshop | retail | 7035.6 | Yes |
| Basement | Workshop | retail | 836.1 | Yes |
| Ground | Office | office | 589.3 | Yes |
| Ground | Office | office | 13.0 | Yes |
| Ground | Office | office | 1100.3 | Yes |
| First | Office | office | 1100.3 | Yes |
| Second | Office | office | 1100.3 | Yes |
| Ground | Laboratory | ancillary | 187.4 | No |
| First | Office | office | 187.4 | Yes |
| Second | Office | office | 187.4 | Yes |
| Ground | Office | office | 134.1 | Yes |
| First | Office | office | 144.0 | Yes |
| Ground | Office | office | 520.1 | Yes |
| Ground | Warehouse | warehouse | 520.1 | No |
| Ground | Office | office | 787.4 | Yes |
| First | Office | office | 787.4 | Yes |
| Second | Office | office | 787.4 | Yes |
| Ground | Office | office | 160.3 | Yes |
| Ground | Warehouse | warehouse | 160.3 | No |
| Basement | Office | office | 566.7 | Yes |
| Ground | Office | office | 566.7 | Yes |
| Ground | Office | office | 644.7 | Yes |
| Ground | Workshop | retail | 190.4 | Yes |
| Ground | Plant Room | plant | 161.9 | No |
| Ground | Office | office | 217.1 | Yes |
| Ground | Office | office | 152.1 | Yes |
| First | Office | office | 63.4 | Yes |
| Ground | Plant Room | plant | 36.0 | No |
VOA rateable value is not market value or an annual rates bill. These figures are preliminary and based on public VOA measurements, not an engineering design. A commercial specialist confirms the cooling design on survey.
Other commercial premises nearby in B66
Other premises in the same area with a cooling profile from public VOA data.