Commercial heating & cooling profile
Warehouse And Premises
CLEEVE ROAD, MIDDLE LITTLETON, EVESHAM, WORCS
Major commercial installation, indicative project
£180,800–£312,800
28881.1 m²
Total measured area
5080.8 m²
Likely conditioned
5
Floors
127
Cooling zones (est.)
Measured floor / use breakdown
| Floor | Description | Use | Area m² | Conditioned? |
|---|---|---|---|---|
| Ground | Chill Store | storage | 2411.1 | No |
| Mezzanine | Internal Storage | storage | 77.5 | No |
| Ground | Area Under Supported Floor | ancillary | 77.5 | No |
| Ground | Cold Store | storage | 65.3 | No |
| Ground | Chill Store | storage | 83.7 | No |
| Ground | Chill Store | storage | 121.1 | No |
| Ground | Chill Store | storage | 589.5 | No |
| Ground | Chill Store | storage | 912.0 | No |
| Ground | Chill Store | storage | 136.2 | No |
| Ground | Internal Storage | storage | 15.6 | No |
| Ground | Works Office | office | 7.3 | Yes |
| Ground | Chill Store | storage | 1257.0 | No |
| Basement | Plant Room | plant | 552.5 | No |
| First | Office | office | 638.1 | Yes |
| First | Plant Room | plant | 72.4 | No |
| First | Warehouse | warehouse | 1109.2 | No |
| First | Plant Room | plant | 45.4 | No |
| First | Cold Store | storage | 48.5 | No |
| First | Office | office | 5.3 | Yes |
| Ground | Internal Storage | storage | 540.0 | No |
| Ground | Cold Store | storage | 237.1 | No |
| Ground | Chill Store | storage | 225.8 | No |
| Mezzanine | Internal Storage | storage | 756.8 | No |
| Ground | Plant Room | plant | 23.9 | No |
| Ground | Workshop | retail | 65.2 | Yes |
| Ground | Area Under Supported Floor | ancillary | 756.8 | No |
| Ground | Plant Room | plant | 109.6 | No |
| Ground | Office | office | 216.7 | Yes |
| First | Office | office | 133.5 | Yes |
| Ground | Chill Store | storage | 2438.5 | No |
| Ground | Locker Room | ancillary | 57.9 | No |
| First | Office | office | 58.2 | Yes |
| Ground | Chill Store | storage | 887.8 | No |
| Ground | Chill Store | storage | 155.2 | No |
| Ground | Cold Store | storage | 97.1 | No |
| Ground | Chill Store | storage | 55.4 | No |
| Ground | Cold Store | storage | 53.3 | No |
| Ground | Internal Storage | storage | 13.4 | No |
| Ground | Plant Room | plant | 4.2 | No |
| Ground | Chill Store | storage | 637.2 | No |
| Ground | Locker Room | ancillary | 108.3 | No |
| Ground | Office | office | 275.1 | Yes |
| First | Office | office | 275.1 | Yes |
| Ground | Plant Room | plant | 26.4 | No |
| Ground | Locker Room | ancillary | 10.3 | No |
| Ground | Locker Room | ancillary | 13.8 | No |
| Ground | Plant Room | plant | 71.9 | No |
| Ground | Chill Store | storage | 1085.5 | No |
| Ground | Works Office | office | 35.1 | Yes |
| Ground | Chill Store | storage | 756.0 | No |
| Ground | External Storage | storage | 103.1 | No |
| Ground | Cold Store | storage | 60.2 | No |
| Ground | Portable Building | ancillary | 17.0 | No |
| Ground | Plant Room | plant | 18.7 | No |
| Ground | Plant Room | plant | 18.4 | No |
| Ground | Plant Room | plant | 86.6 | No |
| Ground | External Storage | storage | 88.5 | No |
| Ground | Plant Room | plant | 59.3 | No |
| Ground | Workshop | retail | 28.2 | Yes |
| Ground | Plant Room | plant | 6.0 | No |
| Ground | Plant Room | plant | 27.9 | No |
| Ground | Plant Room | plant | 27.6 | No |
| Ground | Plant Room | plant | 11.4 | No |
| Ground | Plant Room | plant | 47.3 | No |
| Ground | Plant Room | plant | 160.2 | No |
| Ground | Plant Room | plant | 9.9 | No |
| Ground | External Storage | storage | 73.6 | No |
| Ground | Plant Room | plant | 9.9 | No |
| Ground | Portable Building | ancillary | 143.4 | No |
| Ground | External Storage | storage | 20.9 | No |
| Ground | Plant Room | plant | 8.7 | No |
| Ground | Plant Room | plant | 9.2 | No |
| Ground | Food Processing Areas | ancillary | 2870.9 | No |
| Ground | Warehouse | warehouse | 1133.7 | No |
| Ground | Plant Room | plant | 336.2 | No |
| First | Food Processing Areas | ancillary | 1755.0 | No |
| Second | Office | office | 3343.0 | Yes |
VOA rateable value is not market value or an annual rates bill. These figures are preliminary and based on public VOA measurements, not an engineering design. A commercial specialist confirms the cooling design on survey.