Hot&Cold.energy

We found your home

OAKMERE, KAY LANE

Detached412 m²EPC A93Electric2010 onwards

Estimated boiler replacement

£1,900–£3,200

For a detached like yours · estimated installed cost

FreeNo obligationLocal installers

Your options for this home

Boiler replacement

£1,900–£3,200

Estimated installed cost · 12.5–19 kW

  • Fuel confirmed on survey
  • Suitable for your home size
  • Combi or system options
See details
  • Preliminary heat requirement 12.5–19.0 kW from 412.0 m² and construction era 2010_plus.
  • Heating system type to be confirmed on survey.

New central heating

£9,160–£15,640

Complete system estimate · 14–21.5 kW

  • Boiler / heat source
  • Radiators (~37)
  • Pipework & controls
See details
  • A complete new system priced on ~37 radiators, pipework and a boiler.
  • Radiator count is indicative from floor area and confirmed on survey.

Home air conditioning

£3,800–£5,700

Multi-split system estimate · 4–6 kW · ~3 units

  • Approx. 3 indoor units
  • Heating & cooling
  • Professional installation
See details
  • Total floor area is not the same as conditioned area; this reflects the selected room scenario.

Heating & cooling profile

Based on this property's recorded characteristics, this 412m² post-2010 detached home has a current EPC rating of A93 and its recorded heating. HotAndCold estimates a space-heating requirement of approximately 12.5–19.0kW. This property has relatively strong recorded energy efficiency. The estimated heat demand per square metre is towards the lower end.

Estimated space-heating intensity
3046 W/m²
relatively lowProperty data confidence: Good

Hot&Cold snapshot

Property size
Substantially larger
Energy efficiency
Higher
Heating intensity
Relatively low
Improvement potential
Moderate
Main heating fuel
Non-gas
Cooling requirement
Medium

What stands out about this home

Larger than most EPC-recorded homes nearby
Stronger energy efficiency than nearby homes
Relatively low modelled heating demand per m²
Detached property

Why this estimate?

We calculate estimates using your property's size, type, age, heating fuel and EPC rating, along with typical installation costs — not a professional heat-loss survey.

How we calculated this

412 m²
Floor area
+
detached
Property type
+
EPC A93
Energy rating
Hot&Cold property model
12.5–19 kW
Estimated heating requirement for this property

What we found about your home

Property type
Detached
Floor area
412 m²
Energy rating
EPC A93
Main heating fuel
Electric
Approx. age
2010 onwards
Location
HIGH LEGH, Cheshire East

We use publicly available data and industry models to generate this estimate. A final survey by an installer may vary.

How this home compares locally

Based on 7 EPC-recorded properties nearby.

Floor area
+34%
34% larger than the local median
EPC rating
+18
18 EPC points above the local median
Mains gas
0%
0% of nearby EPC-recorded homes use mains gas
Property type
71%
this property type is 71% of nearby recorded homes

Building

Built form
Detached
Internal area (EPC)
412 m²
Building footprint
~250 m²
Approx. dimensions
~25.8 × 16.1 m
Main building axis
E–W
Estimated floors
2
Nearest building
11.1 m

Footprint & dimensions derived from Overture Maps building data (ODbL). Approximate, not survey-grade.

How this home is constructed & heated

Recorded on its Energy Performance Certificate.

Walls
Average thermal transmittance 0.17 W/m²K
Roof
Average thermal transmittance 0.14 W/m²K
Windows
High performance glazing
Main heating
Ground source heat pump, underfloor, electric
Heating controls
Time and temperature zone control
Hot water
From main system
Floor
Average thermal transmittance 0.12 W/m²K

Energy improvement potential

Current
A93
Potential
A99
+6
Moderate improvement potential

Recommended improvements for this property

Measures from this home’s official Energy Performance Certificate assessment that could raise its rating and cut running costs, specific to OAKMERE, KAY LANE, HIGH LEGH, LYMM, WA13 0TN.

  1. 1
    Wind turbineIndicative cost: £15,000 - £25,000

    A wind turbine provides electricity from wind energy. This electricity is used throughout the home in the same way as the electricity purchased from an energy supplier. The British Wind Energy Association has up-to-date information on suppliers of small-scale wind systems. Wind turbines are not suitable for all properties. The system’s effectiveness depends on local wind speeds and the presence of nearby obstructions, and a site survey should be undertaken by an accredited installer.

Source: the property’s domestic EPC recommendations (open data). Indicative only — get a professional survey before committing to any measure.

Energy rating history

Recorded change: +50 EPC points across 4 certificates.

  1. 2021E43
  2. 2021E42
  3. 2022C73
  4. 2025A93
A
B
C
D
E
F
G
Current: A93Potential: A99

Common questions

How much does a replacement boiler cost for a property like this?+

For this property we estimate an installed cost of £1,900–£3,200. This is indicative and based on the property's size, type and energy characteristics — your final price depends on equipment choice and an installer survey.

What size boiler might this property need?+

Our preliminary model estimates a heat requirement of around 12.5–19 kW. An installer confirms exact sizing on a heat-loss assessment.

How much would air conditioning cost here?+

A multi-split installation is estimated at £3,800–£5,700, depending on how many rooms you want to cool (around 3 indoor units in a typical layout).

Are these guaranteed prices?+

No — they are indicative estimates to help you understand likely costs before speaking to an installer. Your final price depends on equipment choice, installation complexity and a survey.

Other homes nearby

Ready to get exact prices?

Compare no-obligation quotes from vetted local installers for your property.