We found your home
FLAT A, 61 RICHMOND GROVE
Estimated boiler replacement
£1,900–£3,200
For a flat like yours · estimated installed cost
Your options for this home
Boiler replacement
Estimated installed cost · 6.5–8 kW
- Fuel confirmed on survey
- Suitable for your home size
- Combi or system options
See details →
- • Preliminary heat requirement 6.5–8.0 kW from 69.0 m² and construction era 1900_1929.
- • Heating system type to be confirmed on survey.
New central heating
Complete system estimate · 5.5–7 kW
- Boiler / heat source
- Radiators (~6)
- Pipework & controls
See details →
- • A complete new system priced on ~6 radiators, pipework and a boiler.
- • Radiator count is indicative from floor area and confirmed on survey.
Home air conditioning
Multi-split system estimate · 4–6 kW · ~3 units
- Approx. 3 indoor units
- Heating & cooling
- Professional installation
See details →
- • Total floor area is not the same as conditioned area; this reflects the selected room scenario.
Heating & cooling profile
HotAndCold's model combines the recorded floor area, property type and EPC data, so this 69m² flat has a current EPC rating of E42 and its recorded heating. HotAndCold estimates a space-heating requirement of approximately 6.5–8.0kW. This property's recorded energy efficiency is comparatively low. The estimated heat demand per square metre is towards the higher end.
Hot&Cold snapshot
What stands out about this home
Why this estimate?
We calculate estimates using your property's size, type, age, heating fuel and EPC rating, along with typical installation costs — not a professional heat-loss survey.
How we calculated this
What we found about your home
- Property type
- Flat
- Floor area
- 69 m²
- Energy rating
- EPC E42
- Main heating fuel
- Electric
- Approx. age
- 1900–1929
- Location
- MANCHESTER, Manchester
We use publicly available data and industry models to generate this estimate. A final survey by an installer may vary.
How this home compares locally
Based on 102 EPC-recorded properties nearby.
Building
- Built form
- Flat
- Internal area (EPC)
- 69 m²
- Building footprint
- ~89 m²
- Approx. dimensions
- ~13.0 × 9.4 m
- Main building axis
- NE–SW
- Nearest building
- 0.0 m
Footprint & dimensions derived from Overture Maps building data (ODbL). Approximate, not survey-grade.
How this home is constructed & heated
Recorded on its Energy Performance Certificate.
- Walls
- Solid brick, as built, no insulation (assumed)
- Roof
- (another dwelling above)
- Windows
- Fully double glazed
- Main heating
- Electric storage heaters
- Heating controls
- Manual charge control
- Hot water
- Electric immersion, off-peak
- Floor
- Solid, no insulation (assumed)
Energy improvement potential
Recommended improvements for this property
Measures from this home’s official Energy Performance Certificate assessment that could raise its rating and cut running costs, specific to FLAT A, 61 RICHMOND GROVE, MANCHESTER, M13 0DH.
- 1High heat retention storage heaters and dual immersion cylinderIndicative cost: £800 - £1,200
Modern storage heaters have better insulation and are easier to control than the older type in the property. Ask for a quotation for new, high heat retention heaters with automatic charge and output controls. A dual-immersion cylinder, which can be installed at the same time, will provide cheaper hot water than the system currently installed. As installations should be in accordance with the current regulations covering electrical wiring, only a qualified electrician should carry out the installation. It is best to obtain advice from a qualified heating engineer. Ask the engineer to explain
- 2Solar water heatingIndicative cost: £4,000 - £6,000
A solar water heating panel, usually fixed to the roof, uses the sun to pre-heat the hot water supply. This will significantly reduce the demand on the heating system to provide hot water and hence save fuel and money. The Solar Trade Association has up-to-date information on local installers.
- 3High performance external doorsIndicative cost: £1,000
High performance external doors contain insulation and lose heat at about half the rate of conventional external doors.
- 450 mm internal or external wall insulationIndicative cost: £4,000 - £14,000
Solid wall insulation involves adding a layer of insulation to either the inside or the outside surface of the external walls, which reduces heat loss and lowers fuel bills. As it is more expensive than cavity wall insulation it is only recommended for walls without a cavity, or where for technical reasons a cavity cannot be filled. Internal insulation, known as dry-lining, is where a layer of insulation is fixed to the inside surface of external walls; this type of insulation is best applied when rooms require redecorating and can be installed by a competent DIY enthusiast. External solid wall insulation is the application of an insulant and a weather-protective finish to the outside of the wall. This may improve the look of the home, particularly where existing brickwork or rendering is poor, and will provide long-lasting weather protection. Further information can be obtained from the National Insulation Association (www.nationalinsulationassociation.org.uk).
- 5Solar photovoltaic panels, 2.5 kWpIndicative cost: £3,500 - £5,500
A solar PV system is one which converts light directly into electricity via panels placed on the roof with no waste and no emissions. This electricity is used throughout the home in the same way as the electricity purchased from an energy supplier. The British Photovoltaic Association has up-to-date information on local installers who are qualified electricians. It is best to obtain advice from a qualified electrician. Ask the electrician to explain the options.
- 6Floor insulation (solid floor)Indicative cost: £4,000 - £6,000
Insulation of a floor will significantly reduce heat loss; this will improve levels of comfort, reduce energy use and lower fuel bills. Further information about floor insulation is available from many sources including www.energysavingtrust.org.uk/northernireland/Insulation/Floor-insulation.
- 7Add additional 80 mm jacket to hot water cylinderIndicative cost: £15 - £30
Increasing the thickness of existing insulation by adding an 80 mm cylinder jacket around the hot water cylinder will help maintain the water at the required temperature; this will reduce the amount of energy used and lower fuel bills. The jacket should be fitted over the top of the existing foam insulation and over any thermostat clamped to the cylinder. Hot water pipes from the hot water cylinder should also be insulated, using pre-formed pipe insulation of up to 50 mm thickness (or to suit the space available) for as far as they can be accessed to reduce losses in summer. All these materials can be purchased from DIY stores and installed by a competent DIY enthusiast.
Source: the property’s domestic EPC recommendations (open data). Indicative only — get a professional survey before committing to any measure.
Energy rating history
Recorded change: -9 EPC points across 3 certificates.
- 2013E51
- 2022E39
- 2022E42
Common questions
How much does a replacement boiler cost for a property like this?+
For this property we estimate an installed cost of £1,900–£3,200. This is indicative and based on the property's size, type and energy characteristics — your final price depends on equipment choice and an installer survey.
What size boiler might this property need?+
Our preliminary model estimates a heat requirement of around 6.5–8 kW. An installer confirms exact sizing on a heat-loss assessment.
How much would air conditioning cost here?+
A multi-split installation is estimated at £3,800–£5,700, depending on how many rooms you want to cool (around 3 indoor units in a typical layout).
Are these guaranteed prices?+
No — they are indicative estimates to help you understand likely costs before speaking to an installer. Your final price depends on equipment choice, installation complexity and a survey.
Other homes nearby
Ready to get exact prices?
Compare no-obligation quotes from vetted local installers for your property.