We found your home
9 SPRING VALE, PRESTWICH
Estimated boiler replacement
£1,900–£3,200
For a bungalow like yours · estimated installed cost
Your options for this home
Boiler replacement
Estimated installed cost · 11.5–15.5 kW
- Existing mains gas
- Suitable for your home size
- Combi or system options
See details →
- • Preliminary heat requirement 11.5–15.5 kW from 152.0 m² and construction era 1960s.
- • Existing wet central heating assumed where mains gas is present.
New central heating
Complete system estimate · 11.5–15.5 kW
- Boiler / heat source
- Radiators (~14)
- Pipework & controls
See details →
- • A complete new system priced on ~14 radiators, pipework and a boiler.
- • Radiator count is indicative from floor area and confirmed on survey.
Home air conditioning
Multi-split system estimate · 4–6 kW · ~3 units
- Approx. 3 indoor units
- Heating & cooling
- Professional installation
See details →
- • Total floor area is not the same as conditioned area; this reflects the selected room scenario.
Heating & cooling profile
Using the recorded floor area and EPC characteristics, this 152m² 1960s bungalow has a current EPC rating of D66 and mains-gas heating. HotAndCold estimates a space-heating requirement of approximately 11.5–15.5kW. The recorded EPC score places this home in the middle of the efficiency range. The estimated heat demand per square metre is around typical levels.
Hot&Cold snapshot
Why this estimate?
We calculate estimates using your property's size, type, age, heating fuel and EPC rating, along with typical installation costs — not a professional heat-loss survey.
How we calculated this
What we found about your home
- Property type
- Bungalow
- Floor area
- 152 m²
- Energy rating
- EPC D66
- Main heating fuel
- Mains gas
- Approx. age
- 1960s
- Location
- PRESTWICH, Bury
We use publicly available data and industry models to generate this estimate. A final survey by an installer may vary.
How this home compares locally
Based on 9 EPC-recorded properties nearby.
Sale history
Recorded sales for 9 SPRING VALE from HM Land Registry Price Paid data.
- £305,000Dec 2018 · Detached
- £339,950Jun 2005 · Detached
- £148,000Dec 1999 · Detached
Contains HM Land Registry data © Crown copyright and database right. Sale prices are historic and not a current valuation.
Building
- Built form
- Bungalow
- Internal area (EPC)
- 152 m²
- Building footprint
- ~182 m²
- Approx. dimensions
- ~19.2 × 13.0 m
- Main building axis
- N–S
- Estimated floors
- 2
- Nearest building
- 2.2 m
Footprint & dimensions derived from Overture Maps building data (ODbL). Approximate, not survey-grade.
How this home is constructed & heated
Recorded on its Energy Performance Certificate.
- Walls
- Cavity wall, filled cavity
- Roof
- Pitched, 150 mm loft insulation
- Windows
- Mostly double glazing
- Main heating
- Boiler and radiators, mains gas
- Heating controls
- Programmer and room thermostat
- Hot water
- From main system, no cylinder thermostat
- Floor
- Suspended, no insulation (assumed)
Energy improvement potential
Recommended improvements for this property
Measures from this home’s official Energy Performance Certificate assessment that could raise its rating and cut running costs, specific to 9 SPRING VALE, PRESTWICH, MANCHESTER, M25 9SE.
- 1Hot water cylinder thermostatIndicative cost: £200 - £400
A hot water cylinder thermostat enables the boiler to switch off when the water in the cylinder reaches the required temperature; this minimises the amount of energy that is used and lowers fuel bills. The thermostat is a temperature sensor that sends a signal to the boiler when the required temperature is reached. To be fully effective it needs to be sited in the correct position and hard wired in place, so it should be installed by a competent plumber or heating engineer.
- 2Solar photovoltaic panels, 2.5 kWpIndicative cost: £5,000 - £8,000
A solar PV system is one which converts light directly into electricity via panels placed on the roof with no waste and no emissions. This electricity is used throughout the home in the same way as the electricity purchased from an energy supplier. The British Photovoltaic Association has up-to-date information on local installers who are qualified electricians. It is best to obtain advice from a qualified electrician. Ask the electrician to explain the options.
- 3Increase loft insulation to 270 mmIndicative cost: £100 - £350
Loft insulation laid in the loft space or between roof rafters to a depth of at least 270 mm will significantly reduce heat loss through the roof; this will improve levels of comfort, reduce energy use and lower fuel bills. Insulation should not be placed below any cold water storage tank; any such tank should also be insulated on its sides and top, and there should be boarding on battens over the insulation to provide safe access between the loft hatch and the cold water tank. The insulation can be installed by professional contractors but also by a capable DIY enthusiast. Loose granules may be used instead of insulation quilt; this form of loft insulation can be blown into place and can be useful where access is difficult. The loft space must have adequate ventilation to prevent dampness; seek advice about this if unsure (particularly if installing insulation between rafters because a vapour control layer and ventilation above the insulation are required). Further information about loft insulation and details of local contractors can be obtained from the National Insulation Association (www.nationalinsulationassociation.org.uk).
- 4Floor insulation (suspended floor)Indicative cost: £800 - £1,200
Insulation of a floor will significantly reduce heat loss; this will improve levels of comfort, reduce energy use and lower fuel bills. Suspended floors can often be insulated from below. . Further information about floor insulation is available from many sources including www.energysavingtrust.org.uk/northernireland/Insulation/Floor-insulation.
- 5Upgrade heating controlsIndicative cost: £350 - £450
Thermostatic radiator valves allow the temperature of each room to be controlled to suit individual needs, adding to comfort and reducing heating bills provided internal doors are kept closed. For example, they can be set to be warmer in the living room and bathroom than in the bedrooms. Ask a competent heating engineer to install thermostatic radiator valves. Thermostatic radiator valves should be fitted to every radiator except the radiator in the same room as the room thermostat. Remember the room thermostat is needed as well as the thermostatic radiator valves, to enable the boiler to switch off when no heat is required. It is best to obtain advice from a qualified heating engineer.
- 6Solar water heatingIndicative cost: £4,000 - £6,000
A solar water heating panel, usually fixed to the roof, uses the sun to pre-heat the hot water supply. This will significantly reduce the demand on the heating system to provide hot water and hence save fuel and money. The Solar Trade Association has up-to-date information on local installers.
- 7Low energy lighting for all fixed outletsIndicative cost: £60
Replacement of traditional light bulbs with energy saving recommended ones will reduce lighting costs over the lifetime of the bulb, and they last up to 12 times longer than ordinary light bulbs. Also consider selecting low energy light fittings when redecorating; contact the Lighting Association for your nearest stockist of Domestic Energy Efficient Lighting Scheme fittings.
Source: the property’s domestic EPC recommendations (open data). Indicative only — get a professional survey before committing to any measure.
Common questions
How much does a replacement boiler cost for a property like this?+
For this property we estimate an installed cost of £1,900–£3,200. This is indicative and based on the property's size, type and energy characteristics — your final price depends on equipment choice and an installer survey.
What size boiler might this property need?+
Our preliminary model estimates a heat requirement of around 11.5–15.5 kW. An installer confirms exact sizing on a heat-loss assessment.
How much would air conditioning cost here?+
A multi-split installation is estimated at £3,800–£5,700, depending on how many rooms you want to cool (around 3 indoor units in a typical layout).
Are these guaranteed prices?+
No — they are indicative estimates to help you understand likely costs before speaking to an installer. Your final price depends on equipment choice, installation complexity and a survey.
Other homes nearby
Ready to get exact prices?
Compare no-obligation quotes from vetted local installers for your property.