Hot&Cold.energy

We found your home

56 BEVILL SQUARE, SALFORD

Flat60 m²EPC D64Mains gas1960s

Estimated boiler replacement

£1,900–£3,200

For a flat like yours · estimated installed cost

FreeNo obligationLocal installers

Your options for this home

Boiler replacement

£1,900–£3,200

Estimated installed cost · 4–5.5 kW

  • Existing mains gas
  • Suitable for your home size
  • Combi or system options
See details
  • Preliminary heat requirement 4.0–5.5 kW from 60.0 m² and construction era 1960s.
  • Existing wet central heating assumed where mains gas is present.

New central heating

£3,400–£5,400

Complete system estimate · 4–5.5 kW

  • Boiler / heat source
  • Radiators (~5)
  • Pipework & controls
See details
  • A complete new system priced on ~5 radiators, pipework and a boiler.
  • Radiator count is indicative from floor area and confirmed on survey.

Home air conditioning

£3,800–£5,700

Multi-split system estimate · 4–6 kW · ~3 units

  • Approx. 3 indoor units
  • Heating & cooling
  • Professional installation
See details
  • Total floor area is not the same as conditioned area; this reflects the selected room scenario.

Heating & cooling profile

Based on this property's recorded characteristics, this 60m² 1960s flat has a current EPC rating of D64 and mains-gas heating. HotAndCold estimates a space-heating requirement of approximately 4.0–5.5kW. The recorded EPC score places this home in the middle of the efficiency range. Its modelled space-heating intensity per square metre is moderate.

Estimated space-heating intensity
6792 W/m²
moderateProperty data confidence: Good

Hot&Cold snapshot

Property size
Typical
Energy efficiency
Moderate
Heating intensity
Moderate
Improvement potential
Significant
Main heating fuel
Mains gas
Cooling requirement
Medium

What stands out about this home

Modern heating controls recorded

Why this estimate?

We calculate estimates using your property's size, type, age, heating fuel and EPC rating, along with typical installation costs — not a professional heat-loss survey.

How we calculated this

60 m²
Floor area
+
flat
Property type
+
EPC D64
Energy rating
+
Mains gas
Current fuel
Hot&Cold property model
4–5.5 kW
Estimated heating requirement for this property

What we found about your home

Property type
Flat
Floor area
60 m²
Energy rating
EPC D64
Main heating fuel
Mains gas
Approx. age
1960s
Location
SALFORD, Salford

We use publicly available data and industry models to generate this estimate. A final survey by an installer may vary.

How this home compares locally

Based on 49 EPC-recorded properties nearby.

Floor area
-5%
5% smaller than the local median
EPC rating
-4
4 EPC points below the local median
Mains gas
100%
100% of nearby EPC-recorded homes use mains gas
Property type
100%
this property type is 100% of nearby recorded homes

Building

Built form
Flat
Internal area (EPC)
60 m²
Building footprint
~154 m²
Approx. dimensions
~17.7 × 10.1 m
Main building axis
N–S
Nearest building
0.0 m

Footprint & dimensions derived from Overture Maps building data (ODbL). Approximate, not survey-grade.

How this home is constructed & heated

Recorded on its Energy Performance Certificate.

Walls
Cavity wall, filled cavity
Roof
(another dwelling above)
Windows
Fully double glazed
Main heating
Boiler and radiators, mains gas
Heating controls
Programmer, room thermostat and TRVs
Hot water
Electric immersion, standard tariff
Floor
(another dwelling below)

Energy improvement potential

Current
D64
Potential
C77
+13
Significant improvement potential

Recommended improvements for this property

Measures from this home’s official Energy Performance Certificate assessment that could raise its rating and cut running costs, specific to 56 BEVILL SQUARE, SALFORD, M3 6BB.

  1. 1
    Add additional 80 mm jacket to hot water cylinderIndicative cost: £15 - £30

    Increasing the thickness of existing insulation by adding an 80 mm cylinder jacket around the hot water cylinder will help maintain the water at the required temperature; this will reduce the amount of energy used and lower fuel bills. The jacket should be fitted over the top of the existing foam insulation and over any thermostat clamped to the cylinder. Hot water pipes from the hot water cylinder should also be insulated, using pre-formed pipe insulation of up to 50 mm thickness (or to suit the space available) for as far as they can be accessed to reduce losses in summer. All these materials can be purchased from DIY stores and installed by a competent DIY enthusiast.

  2. 2
    Replace boiler with new condensing boilerIndicative cost: £2,200 - £3,000

    A condensing boiler is capable of much higher efficiencies than other types of boiler, meaning it will burn less fuel to heat this property. This improvement is most appropriate when the existing central heating boiler needs repair or replacement, but there may be exceptional circumstances making this impractical. Condensing boilers need a drain for the condensate which limits their location; remember this when considering remodelling the room containing the existing boiler even if the latter is to be retained for the time being (for example a kitchen makeover). It is best to obtain advice from a qualified heating engineer. Ask the engineer to explain the options.

Source: the property’s domestic EPC recommendations (open data). Indicative only — get a professional survey before committing to any measure.

Energy rating history

Recorded change: +10 EPC points across 3 certificates.

  1. 2014E54
  2. 2014D61
  3. 2024D64
A
B
C
D
E
F
G
Current: D64Potential: C77

Common questions

How much does a replacement boiler cost for a property like this?+

For this property we estimate an installed cost of £1,900–£3,200. This is indicative and based on the property's size, type and energy characteristics — your final price depends on equipment choice and an installer survey.

What size boiler might this property need?+

Our preliminary model estimates a heat requirement of around 4–5.5 kW. An installer confirms exact sizing on a heat-loss assessment.

How much would air conditioning cost here?+

A multi-split installation is estimated at £3,800–£5,700, depending on how many rooms you want to cool (around 3 indoor units in a typical layout).

Are these guaranteed prices?+

No — they are indicative estimates to help you understand likely costs before speaking to an installer. Your final price depends on equipment choice, installation complexity and a survey.

Other homes nearby

Ready to get exact prices?

Compare no-obligation quotes from vetted local installers for your property.