We found your home
19, LOCK 5
Estimated boiler replacement
£1,900–£3,200
For a flat like yours · estimated installed cost
Your options for this home
Boiler replacement
Estimated installed cost · 2–2.5 kW
- Fuel confirmed on survey
- Suitable for your home size
- Combi or system options
See details →
- • Preliminary heat requirement 2.0–2.5 kW from 59.0 m² and construction era 2000_2009.
- • Heating system type to be confirmed on survey.
New central heating
Complete system estimate · 2–3 kW
- Boiler / heat source
- Radiators (~5)
- Pipework & controls
See details →
- • A complete new system priced on ~5 radiators, pipework and a boiler.
- • Radiator count is indicative from floor area and confirmed on survey.
Home air conditioning
Multi-split system estimate · 4–6 kW · ~3 units
- Approx. 3 indoor units
- Heating & cooling
- Professional installation
See details →
- • Total floor area is not the same as conditioned area; this reflects the selected room scenario.
Heating & cooling profile
From the available property and energy data, this 59m² 2000s flat has a current EPC rating of C75 and its recorded heating. HotAndCold estimates a space-heating requirement of approximately 2.0–2.5kW. The recorded EPC score is comparatively high for existing housing stock. Its modelled space-heating intensity per square metre is relatively low.
Hot&Cold snapshot
What stands out about this home
Why this estimate?
We calculate estimates using your property's size, type, age, heating fuel and EPC rating, along with typical installation costs, not a professional heat-loss survey.
How we calculated this
What we found about your home
- Property type
- Flat
- Floor area
- 59 m²
- Energy rating
- EPC C75
- Main heating fuel
- Electric
- Approx. age
- 2000–2009
- Location
- RUNCORN, Halton
We use publicly available data and industry models to generate this estimate. A final survey by an installer may vary.
How this home compares locally
Based on 46 EPC-recorded properties nearby.
Building
- Built form
- Flat
- Internal area (EPC)
- 59 m²
- Building footprint
- ~783 m²
- Approx. dimensions
- ~54.0 × 14.5 m
- Main building axis
- E–W
- Estimated floors
- 7
- Nearest building
- 15.1 m
Footprint & dimensions derived from Overture Maps building data (ODbL). Approximate, not survey-grade.
How this home is constructed & heated
Recorded on its Energy Performance Certificate.
- Walls
- System built, as built, insulated (assumed)
- Roof
- (another dwelling above)
- Windows
- Fully double glazed
- Main heating
- Room heaters, electric
- Heating controls
- Programmer and appliance thermostats
- Hot water
- Electric immersion, standard tariff
- Floor
- (another dwelling below)
Energy improvement potential
Recommended improvements for this property
Measures from this home’s official Energy Performance Certificate assessment that could raise its rating and cut running costs, specific to 19, LOCK 5, THE DECKS, RUNCORN, WA7 1GJ.
- 1High heat retention storage heaters and dual immersion cylinderIndicative cost: £1,200 - £1,800
Modern storage heaters are less expensive to run than the direct acting, on-peak heating system in the property. A dual-rate electricity supply is required to provide the off-peak electricity that these heaters use; this is easily obtained by contacting the energy supplier. Ask for a quotation for high heat retention heaters with automatic charge and output controls. A dual-immersion cylinder, which can be installed at the same time, will provide cheaper hot water than the system currently installed. As installations should be in accordance with the national wiring standards, only a qualified electrician should carry out the installation. Ask a qualified electrical heating engineer to explain the options, which might also include switching to other forms of electric heating.
- 2Low energy lighting for all fixed outletsIndicative cost: £30
Replacement of traditional light bulbs with energy saving recommended ones will reduce lighting costs over the lifetime of the bulb, and they last up to 12 times longer than ordinary light bulbs. Also consider selecting low energy light fittings when redecorating; contact the Lighting Association for your nearest stockist of Domestic Energy Efficient Lighting Scheme fittings.
Source: the property’s domestic EPC recommendations (open data). Indicative only, get a professional survey before committing to any measure.
Common questions
How much does a replacement boiler cost for a property like this?+
For this property we estimate an installed cost of £1,900–£3,200. This is indicative and based on the property's size, type and energy characteristics, your final price depends on equipment choice and an installer survey.
What size boiler might this property need?+
Our preliminary model estimates a heat requirement of around 2–2.5 kW. An installer confirms exact sizing on a heat-loss assessment.
How much would air conditioning cost here?+
A multi-split installation is estimated at £3,800–£5,700, depending on how many rooms you want to cool (around 3 indoor units in a typical layout).
Are these guaranteed prices?+
No, they are indicative estimates to help you understand likely costs before speaking to an installer. Your final price depends on equipment choice, installation complexity and a survey.
Other homes nearby
Ready to get exact prices?
Compare no-obligation quotes from vetted local installers for your property.