Hot&Cold.energy

We found your home

1, FAIRFIELD VIEW

Detached95 m²EPC D62Mains gas1950s

Estimated boiler replacement

£1,900–£3,200

For a detached like yours · estimated installed cost

FreeNo obligationLocal installers

Your options for this home

Boiler replacement

£1,900–£3,200

Estimated installed cost · 7.5–10 kW

  • Existing mains gas
  • Suitable for your home size
  • Combi or system options
See details
  • Preliminary heat requirement 7.5–10.0 kW from 95.0 m² and construction era 1950s.
  • Existing wet central heating assumed where mains gas is present.

New central heating

£4,120–£6,680

Complete system estimate · 7.5–10 kW

  • Boiler / heat source
  • Radiators (~9)
  • Pipework & controls
See details
  • A complete new system priced on ~9 radiators, pipework and a boiler.
  • Radiator count is indicative from floor area and confirmed on survey.

Home air conditioning

£3,800–£5,700

Multi-split system estimate · 4–6 kW · ~3 units

  • Approx. 3 indoor units
  • Heating & cooling
  • Professional installation
See details
  • Total floor area is not the same as conditioned area; this reflects the selected room scenario.

Heating & cooling profile

From the available property and energy data, this 95m² 1950s detached home has a current EPC rating of D62 and mains-gas heating. HotAndCold estimates a space-heating requirement of approximately 7.5–10.0kW. This property has moderate recorded energy efficiency — neither especially poor nor especially high. Its modelled space-heating intensity per square metre is moderate.

Estimated space-heating intensity
79105 W/m²
moderateProperty data confidence: Good

Hot&Cold snapshot

Property size
Typical
Energy efficiency
Moderate
Heating intensity
Moderate
Improvement potential
Significant
Main heating fuel
Mains gas
Cooling requirement
Medium

What stands out about this home

Lower energy efficiency than nearby EPC-recorded homes
Detached property

Why this estimate?

We calculate estimates using your property's size, type, age, heating fuel and EPC rating, along with typical installation costs — not a professional heat-loss survey.

How we calculated this

95 m²
Floor area
+
detached
Property type
+
EPC D62
Energy rating
+
Mains gas
Current fuel
Hot&Cold property model
7.5–10 kW
Estimated heating requirement for this property

What we found about your home

Property type
Detached
Floor area
95 m²
Energy rating
EPC D62
Main heating fuel
Mains gas
Approx. age
1950s
Location
AUDENSHAW, Tameside

We use publicly available data and industry models to generate this estimate. A final survey by an installer may vary.

How this home compares locally

Based on 18 EPC-recorded properties nearby.

Floor area
+4%
4% larger than the local median
EPC rating
-11
11 EPC points below the local median
Mains gas
100%
100% of nearby EPC-recorded homes use mains gas
Property type
17%
this property type is 17% of nearby recorded homes

Building

Built form
Detached
Internal area (EPC)
95 m²
Building footprint
~73 m²
Approx. dimensions
~10.2 × 7.2 m
Main building axis
NE–SW
Estimated floors
2
Nearest building
1.1 m

Footprint & dimensions derived from Overture Maps building data (ODbL). Approximate, not survey-grade.

How this home is constructed & heated

Recorded on its Energy Performance Certificate.

Walls
Cavity wall, filled cavity
Roof
Pitched, 100 mm loft insulation
Windows
Fully double glazed
Main heating
Boiler and radiators, mains gas
Heating controls
Programmer and room thermostat
Hot water
From main system
Floor
Suspended, no insulation (assumed)

Energy improvement potential

Current
D62
Potential
C78
+16
Significant improvement potential

Recommended improvements for this property

Measures from this home’s official Energy Performance Certificate assessment that could raise its rating and cut running costs, specific to 1, FAIRFIELD VIEW, BOOTH ROAD, AUDENSHAW, MANCHESTER, M34 5QA.

  1. 1
    Upgrade heating controlsIndicative cost: £350 - £450

    Thermostatic radiator valves allow the temperature of each room to be controlled to suit individual needs, adding to comfort and reducing heating bills provided internal doors are kept closed. For example, they can be set to be warmer in the living room and bathroom than in the bedrooms. Ask a competent heating engineer to install thermostatic radiator valves. Thermostatic radiator valves should be fitted to every radiator except the radiator in the same room as the room thermostat. Remember the room thermostat is needed as well as the thermostatic radiator valves, to enable the boiler to switch off when no heat is required. It is best to obtain advice from a qualified heating engineer.

  2. 2
    Solar water heatingIndicative cost: £4,000 - £6,000

    A solar water heating panel, usually fixed to the roof, uses the sun to pre-heat the hot water supply. This will significantly reduce the demand on the heating system to provide hot water and hence save fuel and money. The Solar Trade Association has up-to-date information on local installers.

  3. 3
    Floor insulation (suspended floor)Indicative cost: £800 - £1,200

    Insulation of a floor will significantly reduce heat loss; this will improve levels of comfort, reduce energy use and lower fuel bills. Suspended floors can often be insulated from below. . Further information about floor insulation is available from many sources including www.energysavingtrust.org.uk/northernireland/Insulation/Floor-insulation.

  4. 4
    Solar photovoltaic panels, 2.5 kWpIndicative cost: £5,000 - £8,000

    A solar PV system is one which converts light directly into electricity via panels placed on the roof with no waste and no emissions. This electricity is used throughout the home in the same way as the electricity purchased from an energy supplier. The British Photovoltaic Association has up-to-date information on local installers who are qualified electricians. It is best to obtain advice from a qualified electrician. Ask the electrician to explain the options.

  5. 5
    Low energy lighting for all fixed outletsIndicative cost: £10

    Replacement of traditional light bulbs with energy saving recommended ones will reduce lighting costs over the lifetime of the bulb, and they last up to 12 times longer than ordinary light bulbs. Also consider selecting low energy light fittings when redecorating; contact the Lighting Association for your nearest stockist of Domestic Energy Efficient Lighting Scheme fittings.

  6. 6
    Increase loft insulation to 270 mmIndicative cost: £100 - £350

    Loft insulation laid in the loft space or between roof rafters to a depth of at least 270 mm will significantly reduce heat loss through the roof; this will improve levels of comfort, reduce energy use and lower fuel bills. Insulation should not be placed below any cold water storage tank; any such tank should also be insulated on its sides and top, and there should be boarding on battens over the insulation to provide safe access between the loft hatch and the cold water tank. The insulation can be installed by professional contractors but also by a capable DIY enthusiast. Loose granules may be used instead of insulation quilt; this form of loft insulation can be blown into place and can be useful where access is difficult. The loft space must have adequate ventilation to prevent dampness; seek advice about this if unsure (particularly if installing insulation between rafters because a vapour control layer and ventilation above the insulation are required). Further information about loft insulation and details of local contractors can be obtained from the National Insulation Association (www.nationalinsulationassociation.org.uk).

Source: the property’s domestic EPC recommendations (open data). Indicative only — get a professional survey before committing to any measure.

A
B
C
D
E
F
G
Current: D62Potential: C78

Common questions

How much does a replacement boiler cost for a property like this?+

For this property we estimate an installed cost of £1,900–£3,200. This is indicative and based on the property's size, type and energy characteristics — your final price depends on equipment choice and an installer survey.

What size boiler might this property need?+

Our preliminary model estimates a heat requirement of around 7.5–10 kW. An installer confirms exact sizing on a heat-loss assessment.

How much would air conditioning cost here?+

A multi-split installation is estimated at £3,800–£5,700, depending on how many rooms you want to cool (around 3 indoor units in a typical layout).

Are these guaranteed prices?+

No — they are indicative estimates to help you understand likely costs before speaking to an installer. Your final price depends on equipment choice, installation complexity and a survey.

Other homes nearby

Ready to get exact prices?

Compare no-obligation quotes from vetted local installers for your property.